The current US 1500 VA / 1000 W CP1500PFCLCD generation provides six backed AC outlets, sine-wave battery output and an included USB management cable. Its 100 W and 200 W runtime estimates and serial-dependent replacement batteries are distinct buying considerations.
Read the runtime conditions and evidence note. Do not interpolate, convert a half-load claim or present this as measured runtime of a particular NAS.
Exact 100 W row in the manufacturer's Runtime, View Table, not a converted half-load claim. See the runtime-conditions field; no installed-system guarantee.
Standard US UPS with installed batteries, integral AC cord, supplied USB A+B Type communication cable, user manual and function guide. Optional RMCARD205 network card is not included. This package is the current 1000 W / twelve-outlet generation. The older 900 W / ten-outlet B&H item 1512415 is not interchangeable. Replacement cartridge must follow the delivered unit's serial prefix: RB1290X2 for CXX; RB1280X2B for CR9, CXF or CQC. The merchant page does not establish that prefix. USB HID communication is not a guarantee of a particular NAS/OS pairing or tested shutdown/restart behavior. Reviewed ordinary US purchase destination. Price and live stock are not tracked; no affiliate relationship is asserted.
US 120 V desktop AC UPS units. DC mini-UPS devices, portable power stations and rack installations are outside this category. Runtime estimates do not establish installed runtime or successful NAS shutdown; check the exact hardware revision, load and communication path.
Open a field explanation or source for its conditions.
Documented specifications and exact purchase packages
Compare the details
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unit
US purchase package
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unitCP1500PFCLCD, 1500 VA / 1000 W, twelve outlets, current color LCD, US 120 V; B&H item 1513053, UPC 649532609642
Standard US UPS with installed batteries, integral AC cord, supplied USB A+B Type communication cable, user manual and function guide. Optional RMCARD205 network card is not included.
This package is the current 1000 W / twelve-outlet generation. The older 900 W / ten-outlet B&H item 1512415 is not interchangeable.
Replacement cartridge must follow the delivered unit's serial prefix: RB1290X2 for CXX; RB1280X2B for CR9, CXF or CQC. The merchant page does not establish that prefix.
USB HID communication is not a guarantee of a particular NAS/OS pairing or tested shutdown/restart behavior.
Reviewed ordinary US purchase destination. Price and live stock are not tracked; no affiliate relationship is asserted.
The documented UPS topology and automatic voltage regulation arrangement.
Retain the maker’s qualifications. Line-interactive operation and AVR do not establish zero transfer time or online double-conversion operation.
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unitLine interactive; single-boost AVRThe manufacturer specifies +11.5% voltage correction. Adjustable sensitivity and inconsistent threshold documentation do not establish a fixed transfer boundary.Sources · 2026-10-03CyberPower: CP1500PFCLCD US 1000 W / twelve-outlet product specifications and runtime tableChecked 2026-10-03. Read the original source and its check date before relying on this value.CyberPower: CP1500PFCLCD 1000 W / twelve-outlet datasheetChecked 2026-10-03. Read the original source and its check date before relying on this value.
Output waveform on battery
The waveform explicitly documented while the UPS runs from its battery.
Keep sine-wave and simulated or stepped output distinct. Do not infer a waveform from a product family or an omitted specification.
The documented AC input plug and output receptacle types for the exact US unit.
Confirm the wall connection, device plugs and adapter spacing. Total outlet count alone does not establish that every power adapter will fit.
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unitNEMA 5-15P input; NEMA 5-15R AC outletsIntegral 5 ft input cord. Front USB Type-A and Type-C ports provide 5 V charging with 3.1 A shared; they are separate from the rear USB management connection.Sources · 2026-10-03CyberPower: CP1500PFCLCD US 1000 W / twelve-outlet product specifications and runtime tableChecked 2026-10-03. Read the original source and its check date before relying on this value.CyberPower: CP1500PFCLCD 1000 W / twelve-outlet datasheetChecked 2026-10-03. Read the original source and its check date before relying on this value.
Qualified transfer time
The source’s transfer-time claim with its typical, maximum or other qualification retained.
Do not turn a typical figure into a guaranteed maximum. Device power-supply tolerance and the complete installation still need verification.
Whether the UPS documents a USB data interface for monitoring power status.
This is not a NAS compatibility verdict. USB charging ports do not establish monitoring, and successful detection alone does not prove shutdown or restart.
Documented network management hardware and protocol support, distinguishing included, optional and unavailable equipment.
An RJ45 surge-protection jack is not a network management interface. NAS network-server relay is a separate software configuration, not a built-in UPS network card.
The documented replacement battery part, including any model revision or serial-prefix conditions.
Check the delivered unit’s label before ordering. A merchant model name alone cannot select a battery when serial-dependent replacements exist.
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unitRB1290X2: CXX serial prefix; RB1280X2B: CR9, CXF or CQCOne replacement cartridge contains the pair of batteries. The current specifications list two 12 V / 9 Ah sealed lead-acid batteries. Check the actual unit serial; the merchant model name does not establish which cartridge it needs. User-replaceable, not hot-swappable.Sources · 2026-10-03CyberPower: CP1500PFCLCD US 1000 W / twelve-outlet product specifications and runtime tableChecked 2026-10-03. Read the original source and its check date before relying on this value.CyberPower: CP1500PFCLCD 1000 W / twelve-outlet datasheetChecked 2026-10-03. Read the original source and its check date before relying on this value.
Manufacturer runtime at 100 W
A directly documented runtime estimate at a total 100 W load for this revision.
Read the runtime conditions and evidence note. Do not interpolate, convert a half-load claim or present this as measured runtime of a particular NAS.
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unit66 minExact 100 W row in the manufacturer's Runtime, View Table, not a converted half-load claim. See the runtime-conditions field; no installed-system guarantee.Source · 2026-10-03CyberPower: CP1500PFCLCD US 1000 W / twelve-outlet product specifications and runtime tableChecked 2026-10-03. Read the original source and its check date before relying on this value.
Manufacturer runtime at 200 W
A directly documented runtime estimate at a total 200 W load for this revision.
Compare only the same load and compatible stated conditions. Reserve shutdown time; actual load, charge, age and environment can shorten operation.
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unit30.8 minExact 200 W row in the manufacturer's Runtime, View Table, not interpolated. See the runtime-conditions field; reserve time for shutdown.Source · 2026-10-03CyberPower: CP1500PFCLCD US 1000 W / twelve-outlet product specifications and runtime tableChecked 2026-10-03. Read the original source and its check date before relying on this value.
Runtime estimate conditions
The stated battery, load and environmental conditions behind the documented runtime estimates, with omissions retained.
Manufacturer estimates are separate from CompareFoundry measurements. A new, fully charged battery estimate is not an installed-system guarantee.
CP1500PFCLCD 1000 W / twelve-outlet US 120 V unitManufacturer estimate with fully charged, new batteries under normal operating conditions; battery age, charge and environment affect runtime. Numeric test temperature and load power factor are not stated.These values are manufacturer estimates, not CompareFoundry measurements. Model load ratings and outlet counts do not determine an installation's actual consumption.Source · 2026-10-03CyberPower: CP1500PFCLCD US 1000 W / twelve-outlet product specifications and runtime tableChecked 2026-10-03. Read the original source and its check date before relying on this value.
Unit weight
Published unit weight for the reviewed configuration, with battery scope qualified by the source.
Keep shipping weight separate. Plan a stable location with the manufacturer’s required ventilation and access.
This identity is the current 1000 W / twelve-outlet generation, not the older 900 W / ten-outlet product sold under the same base model name. Historical exact-name compatibility reports do not establish support for this revision.
Replacement cartridge depends on the actual serial prefix: RB1290X2 for CXX; RB1280X2B for CR9, CXF or CQC. A merchant listing does not reveal the serial of a unit that will ship.
The manual's technical table incorrectly labels five UPS outlets; its own description and current product page/datasheet show six backed and six surge-only outlets. Its generic battery instruction omits current serial conditions.
No physical runtime or NAS shutdown/restart test was performed. USB HID and optional network-card support do not prove a particular NAS/OS pairing or cross-vendor shutdown-server interoperability.
Manual and datasheet software-edition references differ. No PowerPanel edition entitlement is asserted.
Body measurements are not installation clearance; current metric dimensions and the manual's rounded dimensions differ slightly.
Allow Google Analytics to measure page visits, engagement and clicks to sellers? It uses analytics cookies. Your choice won’t affect the comparison tools. Read our privacy policy.