PM2.5 sensing
CO2, particles and gases are different quantities. One sensor does not measure all of them.
The manual refers to a particulate matter sensor and lists a 0–999.9 μg/m3 PM2.5 range.
US catalogue
Temtop / Indoor air quality monitors
A rechargeable E-ink monitor reporting PM2.5, CO2, a TVOC index, AQI, temperature and humidity, with Bluetooth pairing and 2.4 GHz Wi-Fi app sync; the CO2 sensing method is not stated.
No community reviews yet.
CO2, particles and gases are different quantities. One sensor does not measure all of them.
The manual refers to a particulate matter sensor and lists a 0–999.9 μg/m3 PM2.5 range.
Keep sensor presence separate from professional test certification, local rules and interpretation of results.
Radon is not part of the documented 6-in-1 set.
A coloured indicator is not a numeric display. App readings are a separate viewing route.
The E-ink screen cycles PM2.5, AQI, CO2 and TVOC screens with temperature and humidity shown on each.
One standard consumer monitor in the specified US selection. Optional hubs, extra sensors and commercial services are not assumed included. Manual box list: detector, manual and USB cable; no wall adapter.
Select: Temtop M10+ WIFI, SKU M10+ WIFI; not M10 or M10+ without Wi-Fi.
View at Temtop US — M10+ WIFI (US selection); opens in a new tabThe link may open several packages. Check current price and availability with the seller. Opens in a new tab.
Consumer monitoring packages for US buyers. These comparisons do not certify indoor safety, diagnose health conditions or replace dedicated smoke/CO alarms or professional testing.
Open a field explanation or source for its conditions.
| Compare the details | M10+ WIFI (US selection) |
|---|---|
| US purchase package | Temtop M10+ WIFI, SKU M10+ WIFI; not M10 or M10+ without Wi-Fi. One standard consumer monitor in the specified US selection. Optional hubs, extra sensors and commercial services are not assumed included. Manual box list: detector, manual and USB cable; no wall adapter. Sources · 2026-10-21Temtop: Temtop M10+ WIFI US store pageChecked 2026-10-21. We reviewed the official page text on the check date. Checkout options were not verified.Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
Direct CO2 sensingWhether a dedicated CO2 sensing method is documented. Do not substitute derived eCO2 from another gas sensor for a direct CO2 measurement. | Not verifiedWe have not verified this value. It is not a confirmed no or zero. Check the original source or ask the manufacturer if it affects your choice. Sources · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value.Temtop: Temtop M10+ WIFI US store pageChecked 2026-10-21. We reviewed the official page text on the check date. Checkout options were not verified. |
CO2 method and revisionThe manufacturer-described CO2 sensing technology. The method alone does not establish calibrated accuracy or identical behavior between revisions. | Not verifiedWe have not verified this value. It is not a confirmed no or zero. Check the original source or ask the manufacturer if it affects your choice. Sources · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value.Temtop: Temtop M10+ WIFI US store pageChecked 2026-10-21. We reviewed the official page text on the check date. Checkout options were not verified. |
PM2.5 sensingWhether a particle sensor for PM2.5 is documented. CO2, particles and gases are different quantities. One sensor does not measure all of them. | YesThe manual refers to a particulate matter sensor and lists a 0–999.9 μg/m3 PM2.5 range.Sources · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value.Temtop: Temtop M10+ WIFI US store pageChecked 2026-10-21. We reviewed the official page text on the check date. Checkout options were not verified. |
Radon sensingWhether the product includes a documented radon sensor. Keep sensor presence separate from professional test certification, local rules and interpretation of results. | NoRadon is not part of the documented 6-in-1 set.Sources · 2026-10-21Temtop: Temtop M10+ WIFI US store pageChecked 2026-10-21. We reviewed the official page text on the check date. Checkout options were not verified.Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
VOC signal typeThe documented VOC-related output or its absence. A relative index, total-VOC estimate and compound-specific concentration are not interchangeable. | Relative TVOC index from 1 to 500; not a concentration or compound-specific value.Source · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
Temperature and humidityWhether both temperature and relative humidity sensing are documented. Use the placement and operating conditions in the manual; a shared room does not imply identical readings. | YesSource · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
Numeric display on the deviceWhether the device itself displays numeric readings. A coloured indicator is not a numeric display. App readings are a separate viewing route. | YesThe E-ink screen cycles PM2.5, AQI, CO2 and TVOC screens with temperature and humidity shown on each.Source · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
Data connectionThe documented local or internet connection path. Bluetooth synchronization does not by itself provide remote access from outside the home. | Bluetooth for pairing and 2.4 GHz Wi-Fi for remote data sync; 5 GHz Wi-Fi is not supported.Once Wi-Fi connects, Bluetooth stops transmitting data.Source · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
Power and included equipmentPower source and relevant package equipment. A supplied USB cable does not establish a supplied wall adapter. Battery life depends on usage and settings. | Built-in 2200mAh rechargeable battery; DC 5V 1A input; USB cable included, no power adapter listed.Temtop's battery-life figures depend on the recording interval and are not a guarantee.Source · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value. |
History, export and service conditionsDocumented ways to view or retain data and the applicable service limits. Local readings, a cloud dashboard, export and commercial API rights are different entitlements. | Temtop app shows live data, history curves and export, with 1, 5, 10 or 30-minute recording intervals; the device caches data while offline.An app account is required; cloud retention terms were not verified.Sources · 2026-10-21Temtop: M10+ WIFI Air Quality Monitor user manual (EN)Checked 2026-10-21. Read the original source and its check date before relying on this value.Temtop: Temtop M10+ WIFI US store pageChecked 2026-10-21. We reviewed the official page text on the check date. Checkout options were not verified. |
| Questions to check before buying | M10, M10+ and M10+ WIFI are separate Temtop products; only the M10+ WIFI manual and store listing are used. The CO2 sensing technology is not documented, so direct CO2 sensing remains unverified. |