UPS battery backups / Comparison

See what changes

Choose up to five exact US purchase options. Compare documented differences and open each source for its conditions.

Add up to three more options
Reset selection

1 of 5 options selected. Bookmark this address to keep your selection.

US 120 V desktop AC UPS units. DC mini-UPS devices, portable power stations and rack installations are outside this category. Runtime estimates do not establish installed runtime or successful NAS shutdown; check the exact hardware revision, load and communication path.

Scroll sideways to see every option. Open a field explanation or source for its conditions.

Documented specifications and exact purchase packages
Compare the detailsBack-UPS Pro BR1500MS2 US 120 V unit
US purchase packageBR1500MS2 Back-UPS Pro, 1500 VA / 900 W, 120 V, ten NEMA 5-15R outlets; GTIN 731304426103

Product & sources

Standard exact BR1500MS2 US unit with installed battery and supplied USB communication cable. The optional serial communication cable is not included.

Preserve the MS2 suffix and 120 V region. BR1500MS and other regional suffixes are separate product identities.

The rear Data Port supports the supplied communication cable. Front USB Type-A/Type-C ports charge devices; Ethernet IN/OUT sockets provide surge protection.

Official transfer-time and body-dimension conflicts remain unresolved. Runtime-calculator test conditions are not fully stated.

Reviewed ordinary US purchase destination. Price and live stock are not tracked; no affiliate relationship is asserted.

Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Where to buy

Select: BR1500MS2 Back-UPS Pro, 1500 VA / 900 W, 120 V, ten NEMA 5-15R outlets; GTIN 731304426103

View at APC by Schneider Electric — Back-UPS Pro BR1500MS2 US 120 V unit; opens in a new tab

The link may open several packages. Check current price and availability with the seller. Opens in a new tab.

1500 VAApparent-power rating, separate from the 900 W real-power limit.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
900 WManufacturer rated real-power capacity for the exact BR1500MS2, not BR1500MS or another regional suffix.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
120 VUS 120 V AC version; preserve the MS2 suffix.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Line interactive; boost and trim AVRThe BR1500MS2 manual table specifies +11.5% boost below its input limit and -11.5% trim above it. This is not an online double-conversion UPS.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Sine waveThe BR1500MS2 table specifies sine-wave battery output. Other models in this shared manual use different waveforms and must not be substituted.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
6 outletsSix NEMA 5-15R AC outlets provide battery backup and surge protection.
Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.
4 outletsFour NEMA 5-15R AC outlets provide surge protection only.
Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.
NEMA 5-15P input; ten NEMA 5-15R AC outletsUS input cord is specified as 6 ft. Front Type-A and Type-C USB charging ports share 15 W; the rear management Data Port is separate.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Sources disagree

The sources give different answers, so we have not chosen one as fact. Read the attached notes and confirm the current specification before relying on it.

The current US page states 8 ms typical / 10 ms maximum; the April 2026 BR1500MS2 manual table states 8 ms maximum. Numeric load and transfer-test conditions are not supplied. Do not choose one limit as resolved.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
YesThe manual directs the supplied USB communication cable from the rear Data Port to the protected device. This is a data connection, separate from front charging; exact NAS/OS support and shutdown/restart behavior are not established.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
YesInventory and connection instructions confirm the supplied USB communication cable. An optional serial cable is not supplied. The rear Data Port connection must not be described as a standard USB Type-B socket without exact connector evidence.
Source · 2026-10-03APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Not verified

We have not verified this value. It is not a confirmed no or zero. Check the original source or ask the manufacturer if it affects your choice.

The reviewed sources establish USB and optional serial communication, not an IP management interface or network-card entitlement. Ethernet IN/OUT sockets provide surge protection and are not network management.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
APCRBC163Exact BR1500MS2 replacement cartridge in the current US page and April 2026 manual page 17. Lead-acid and user-replaceable; do not substitute another BR1500 model's cartridge.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
73 minVisible manufacturer runtime calculator set to exactly 100 W. This is an estimate, not an independent measurement or a value derived from half-load runtime.
Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.
36 minVisible manufacturer runtime calculator set to exactly 200 W. This is an estimate, not an interpolation; reserve shutdown time.
Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.
Manufacturer runtime-calculator estimate at the stated absolute load. Battery age, charge state, ambient temperature and load power factor are not stated; real runtime varies.The reviewed calculator did not state the same new-battery/full-charge conditions used on the CyberPower pages. Do not claim the manufacturers' tests share controlled conditions.
Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.
12.5 kgManufacturer product weight, also stated as 27.6 lb. This is not shipping weight.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Sources disagree

The sources give different answers, so we have not chosen one as fact. Read the attached notes and confirm the current specification before relying on it.

The current page labels H 260 x W 100 x D 368 mm. Manual page 16 lists 11.9 x 4.4 x 15.0 in with 368 x 100 x 260 mm and no axis labels in that row; the two unit representations are internally inconsistent. Resolved dimensions remain unknown; no installation-fit claim.
Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value.
Questions to check before buying

Transfer time is conflicting: current US page 8 ms typical / 10 ms maximum versus April 2026 manual 8 ms maximum. No resolved transfer limit is asserted.

Body dimensions are conflicting, including internally inconsistent inch/mm values in the current linked manual. No body-size or installation-fit assertion is resolved.

The manufacturer runtime calculator supplies the exact 100 W and 200 W estimates, but does not state battery age, charge state, numeric ambient temperature or load power factor. These conditions are not assumed to match CyberPower's.

No physical USB shutdown, power-outage or restoration test was performed. A supplied data cable does not establish exact NAS/firmware compatibility.

Network management is unknown from the reviewed sources. Ethernet surge-protection connectors must not be treated as a network management interface.