UPS battery backups / Comparison
See what changes
Choose up to five exact US purchase options. Compare documented differences and open each source for its conditions.
US 120 V desktop AC UPS units. DC mini-UPS devices, portable power stations and rack installations are outside this category. Runtime estimates do not establish installed runtime or successful NAS shutdown; check the exact hardware revision, load and communication path.
Scroll sideways to see every option. Open a field explanation or source for its conditions.
| Compare the details | Back-UPS Pro BR1500MS2 US 120 V unit |
|---|---|
| US purchase package | BR1500MS2 Back-UPS Pro, 1500 VA / 900 W, 120 V, ten NEMA 5-15R outlets; GTIN 731304426103 Standard exact BR1500MS2 US unit with installed battery and supplied USB communication cable. The optional serial communication cable is not included. Preserve the MS2 suffix and 120 V region. BR1500MS and other regional suffixes are separate product identities. The rear Data Port supports the supplied communication cable. Front USB Type-A/Type-C ports charge devices; Ethernet IN/OUT sockets provide surge protection. Official transfer-time and body-dimension conflicts remain unresolved. Runtime-calculator test conditions are not fully stated. Reviewed ordinary US purchase destination. Price and live stock are not tracked; no affiliate relationship is asserted. Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
| Where to buy | Select: BR1500MS2 Back-UPS Pro, 1500 VA / 900 W, 120 V, ten NEMA 5-15R outlets; GTIN 731304426103 View at APC by Schneider Electric — Back-UPS Pro BR1500MS2 US 120 V unit; opens in a new tabThe link may open several packages. Check current price and availability with the seller. Opens in a new tab. |
Rated apparent outputThe manufacturer-rated apparent-power output limit of the exact UPS revision. Check this alongside its separate continuous watt limit. A larger VA rating does not by itself establish longer runtime. | 1500 VAApparent-power rating, separate from the 900 W real-power limit.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Continuous output limitThe documented continuous real-power output limit of the exact UPS revision. Allow for every backed device and startup requirements. This is a capacity limit, not measured consumption or a runtime estimate. | 900 WManufacturer rated real-power capacity for the exact BR1500MS2, not BR1500MS or another regional suffix.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Nominal input voltageThe nominal AC input voltage specified for the reviewed US unit. A similar regional model name does not establish matching voltage, plugs or output behavior. | 120 VUS 120 V AC version; preserve the MS2 suffix.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Topology and voltage regulationThe documented UPS topology and automatic voltage regulation arrangement. Retain the maker’s qualifications. Line-interactive operation and AVR do not establish zero transfer time or online double-conversion operation. | Line interactive; boost and trim AVRThe BR1500MS2 manual table specifies +11.5% boost below its input limit and -11.5% trim above it. This is not an online double-conversion UPS.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Output waveform on batteryThe waveform explicitly documented while the UPS runs from its battery. Keep sine-wave and simulated or stepped output distinct. Do not infer a waveform from a product family or an omitted specification. | Sine waveThe BR1500MS2 table specifies sine-wave battery output. Other models in this shared manual use different waveforms and must not be substituted.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Battery-backed AC outletsThe number of AC receptacles supplied by the battery during an outage. Count the outlets needed by all backed equipment and check plug spacing. Surge-only outlets do not keep equipment powered. | 6 outletsSix NEMA 5-15R AC outlets provide battery backup and surge protection.Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value. |
Surge-only AC outletsThe number of AC receptacles with surge protection but no battery backup. A known zero means no surge-only outlets. An unknown count is not zero, and these outlets cannot power outage-critical network equipment. | 4 outletsFour NEMA 5-15R AC outlets provide surge protection only.Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value. |
AC input and outlet connectorsThe documented AC input plug and output receptacle types for the exact US unit. Confirm the wall connection, device plugs and adapter spacing. Total outlet count alone does not establish that every power adapter will fit. | NEMA 5-15P input; ten NEMA 5-15R AC outletsUS input cord is specified as 6 ft. Front Type-A and Type-C USB charging ports share 15 W; the rear management Data Port is separate.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Qualified transfer timeThe source’s transfer-time claim with its typical, maximum or other qualification retained. Do not turn a typical figure into a guaranteed maximum. Device power-supply tolerance and the complete installation still need verification. | Sources disagreeThe sources give different answers, so we have not chosen one as fact. Read the attached notes and confirm the current specification before relying on it. Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
USB power monitoringWhether the UPS documents a USB data interface for monitoring power status. This is not a NAS compatibility verdict. USB charging ports do not establish monitoring, and successful detection alone does not prove shutdown or restart. | YesThe manual directs the supplied USB communication cable from the rear Data Port to the protected device. This is a data connection, separate from front charging; exact NAS/OS support and shutdown/restart behavior are not established.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
USB monitoring cable includedWhether the exact package documents the USB data cable needed for its monitoring connection. Check both cable ends and the receiving device. Included charging cables and optional management cables do not establish this field. | YesInventory and connection instructions confirm the supplied USB communication cable. An optional serial cable is not supplied. The rear Data Port connection must not be described as a standard USB Type-B socket without exact connector evidence.Source · 2026-10-03APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Network management scopeDocumented network management hardware and protocol support, distinguishing included, optional and unavailable equipment. An RJ45 surge-protection jack is not a network management interface. NAS network-server relay is a separate software configuration, not a built-in UPS network card. | Not verifiedWe have not verified this value. It is not a confirmed no or zero. Check the original source or ask the manufacturer if it affects your choice. Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Replacement battery and revisionThe documented replacement battery part, including any model revision or serial-prefix conditions. Check the delivered unit’s label before ordering. A merchant model name alone cannot select a battery when serial-dependent replacements exist. | APCRBC163Exact BR1500MS2 replacement cartridge in the current US page and April 2026 manual page 17. Lead-acid and user-replaceable; do not substitute another BR1500 model's cartridge.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Manufacturer runtime at 100 WA directly documented runtime estimate at a total 100 W load for this revision. Read the runtime conditions and evidence note. Do not interpolate, convert a half-load claim or present this as measured runtime of a particular NAS. | 73 minVisible manufacturer runtime calculator set to exactly 100 W. This is an estimate, not an independent measurement or a value derived from half-load runtime.Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value. |
Manufacturer runtime at 200 WA directly documented runtime estimate at a total 200 W load for this revision. Compare only the same load and compatible stated conditions. Reserve shutdown time; actual load, charge, age and environment can shorten operation. | 36 minVisible manufacturer runtime calculator set to exactly 200 W. This is an estimate, not an interpolation; reserve shutdown time.Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value. |
Runtime estimate conditionsThe stated battery, load and environmental conditions behind the documented runtime estimates, with omissions retained. Manufacturer estimates are separate from CompareFoundry measurements. A new, fully charged battery estimate is not an installed-system guarantee. | Manufacturer runtime-calculator estimate at the stated absolute load. Battery age, charge state, ambient temperature and load power factor are not stated; real runtime varies.The reviewed calculator did not state the same new-battery/full-charge conditions used on the CyberPower pages. Do not claim the manufacturers' tests share controlled conditions.Source · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value. |
Unit weightPublished unit weight for the reviewed configuration, with battery scope qualified by the source. Keep shipping weight separate. Plan a stable location with the manufacturer’s required ventilation and access. | 12.5 kgManufacturer product weight, also stated as 27.6 lb. This is not shipping weight.Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
Body dimensionsPublished body dimensions with the source’s axis order and units. Body measurements are not installation clearance. Allow for plugs, cable bends, ventilation and battery replacement access. | Sources disagreeThe sources give different answers, so we have not chosen one as fact. Read the attached notes and confirm the current specification before relying on it. Sources · 2026-10-03APC by Schneider Electric: BR1500MS2 US purchase page, specifications and runtime calculatorChecked 2026-10-03. Read the original source and its check date before relying on this value.APC by Schneider Electric: Back-UPS Pro 120 Vac user guide EN JPT92208, April 2026Checked 2026-10-03. Read the original source and its check date before relying on this value. |
| Questions to check before buying | Transfer time is conflicting: current US page 8 ms typical / 10 ms maximum versus April 2026 manual 8 ms maximum. No resolved transfer limit is asserted. Body dimensions are conflicting, including internally inconsistent inch/mm values in the current linked manual. No body-size or installation-fit assertion is resolved. The manufacturer runtime calculator supplies the exact 100 W and 200 W estimates, but does not state battery age, charge state, numeric ambient temperature or load power factor. These conditions are not assumed to match CyberPower's. No physical USB shutdown, power-outage or restoration test was performed. A supplied data cable does not establish exact NAS/firmware compatibility. Network management is unknown from the reviewed sources. Ethernet surge-protection connectors must not be treated as a network management interface. |